Environment Testing Instruments
a) MODEL-KM 918A
General Specification -
- Temperature range : -10oC ~ 60oC / (14oF ~ 140oF)
- Temperature accuracy : ± 1oC / (± 1.8oF)
- Temperature resolution : 0.1oC / oF
- Humidity range : 20% RH ~ 95 % RH
- Humidity resolution : 1 % RH
- Humidity Accuracy : 8 % RH
- Clock, Temperature and Humidity display
- Room and outside temperature
- Room Humidity display
- Maximum or minimum memorization function
- Alarm clock function at a desired hour.
- Power : 1.5V DC AAA battery
b) MODEL-KM936
Special Features -- Display : 3½ Digit LCD Display
- Ranges : -50oC ~ 1300oC / -58oF ~ 1999oF
- Data hold, oF/ o C, Max. hold function
c) MODEL-KM-963/KM-963P
Special Features (MODEL KM 963) -- Measuring Range : 5% ~ 40%
- Resolution : 1%
- Accuracy : ± 1%
- Power : 9V Alkaline/ Standard battery
- Dimensions : 126(L) x 70(W) x 29(H)(mm)
Special Features (MODEL KM 963P) -
- Description : Digital intelligent MCU paper moisture Meter works on 3 types of paper (carton, copperplate paper, writing paper) by using the spring contact for precise measurement.
- Range : 0 - 40%
- Display : LCD
- Resolution : 1 %
- Operating Temperature : 0oC ~ 50oC, 20 ~ 90% RH .
- Dimension : 126 (L) X 70 (W) X 29 (H) mm
- Power : 9V battery
- Low battery indication
- Weight : 82 gm (without battery)
d) MODEL-MS6701
Features -- Display: 2000 counts
- Frequency range: 30Hz~ 8KHz
- Data logging: 16000 records
- Analog bar indication
- Auto range & manual range
- Auto power off
- Fast/Slow selection
- MAX value hold function
- A/C weighting selection
- USB Interface
- Display Backlight
- Low Battery display
Specification -
Measurement range: | 30dB~130dB |
Accuracy: | ±2dB |
Resolution: | O.ldB |
Display: | 2000 counts |
Sample rate: | 2 times/s |
Frequency range: | 30Hz~8KHz |
Data logging: | 16000 records |
Over range Indication: | "UNDER"/ "OVER" |
Auxiliary output: | AC: 0.707 Vrms at full range for each level, impedance 600Q DC: lOmV/dB, impedance 100O |
Analog bar indication Auto range & manual range Auto power off Fast/Slow selection MAX value hold function A/C weighting selection Date and Time display USB Interface Display Backlight Low Battery display |
|
General | |
Power Supply | 6x1.5V AAA batteries |
Product Size | 245mmx80mmx35mm / 9.6"x3.1"xl.4" |
Product Weight | 350gA8lb |
Category | CE |
e) MODEL-MS6450
Features -- Measurement range: 0.6m~ 15m (2feet ~50feet)
- Accuracy: ±(0.5%+1)
- Resolution: 0.01m(1 feet)
- m/feet unit selection
- Area & Volume calculating
- Laser pointer
- Display backlight
Specification -
Laser pointer
Measurement range: |
0.6m" 15m (2feet ~50feet) |
Accuracy: |
±(0.5%+l) |
Resolution: |
0.0lm (l feet) |
m/feet unit selection | |
Area & Volume calculating | |
Display backlight | |
General | |
Power Supply | 1x9V 6F22 Battery |
Product Size | 136mm x 59mm x 38mm / 5.4" x 2.3" x l.5" |
Product Weight | 150gj0.3lb |
Category | CE |
f) MODEL-WACO MT6
Display 3½ digit (1999 count )
Range -30`C to 550`C/ -22`F-1022`F
Accuracy ± 2`C
Adjustable Emissivity 0.0 - 1.00
Field of view 100mmø at 1000mm
Wave Length Red ( 630-670 mm )
Auto data hold, Max/Min record function
g) CHY-115 (COATING THICKNESS GAUGE)
- Display : 3½ digit (1999 count )
- Technical : 0 - 40.0 mils/1µm
0.1 mils/1µm
1 second
± (4 digits ) on 0-7.80 µm
± (7 digits ) on 0-199 µm
Back light, µm mils user selective, Auto Power off ferrite material use
± ( 3% + 4 digits ) on 7.9mils - 4 mils
h) MODEL-LX-101
* 2,000/ 20,000/ 50,000 Lux , Zero adj.
* 2 filters, spectrum meet C.I.E.
i) MODEL-AM 4202
0.4 to 25.0 m/s., m/s , ft /min, km/h, knots,
Temperature, Data hold , 18 mm LCD
Low -friction ball -bearing vane
j) MODEL-AM 4222
*Air velocity : 0.4 to 30.0 m/s
Temperature : 0 to 50ºC, ºC/ºF.
*Unit : m/s, km/h, knots, ft/min, mile/h.
*Temp: 0 to 50ºC, ºC/ºF.
* All in one, compact and hand held type.
*LCD display, Data hold.
*DC 1.5V battery (UM-4, AAA ) X4.
k) MODEL-CC421
* Current ource :0 to 24 mA, 2 ranges.
* Current measurement : 0 to 24 mA, 2ranges.
*Power (12 V) and current measurement of two
wire loop : 0 to 24 mA, 2 ranges.
*DC mV source :-199.9mV to+199.9mV.
l) MODEL-SL-4001
m) MODEL-DO-5510
µ-P circuit , LCD with display unit
Dissolved oxygen range : 0 to 20 mg/L.
Max., Min., Memory recall button
DO, Oxygen in air Temp ., ATC Auto Cal ., % salt.
Diaphragms & electrolyte included
Probe head with diaphragm set and electrolyte are included
Size : 180 x 72 x 32 mm. RS232 /USB interface
n) INFRARED THERMOMETER SERIES